Data Processing¶
Once you have captured an object from all desired angles and created a sufficient number of scans, you can then build a 3D model. This chapter offers a detailed description of the process.
The process of creating the final model includes the following stages:
See also
- Revising Scans and Editing Scans
- Scan Alignment
- Global Registration
- Creating Models (Fusion)
- Editing Models
- Texturing
Maximum Error and Registration Quality¶
Max error is the parameter that reflects frame registration quality. For scans, it shows the maximum value among all the frames. The larger the value, the less accurate the alignment. Artec Studio displays noteworthy values only for scans that have passed Fine registration, Align and Global registration.
Scanner type | Max error | Recommendations |
---|---|---|
All | 0–0.2 | Good results |
All | >10 | Run registration |
Spider | 0–0.3 | Acceptable unless high resolution is required |
Spider | 0.4–0.5 | Acceptable for large objects |
Spider | >0.6 | Unacceptable |
Eva | 0.4–0.7 | Acceptable for small objects |
Eva | 0.8–1.2 | Acceptable for large objects and unacceptable for small ones |
Eva | >1.2 | Acceptable for large objects |
— | Warning! | Check the frame list |
— | Failed | Indicates unregistered frames |
Revising Scans¶
As you begin building a 3D model, you may want to start by preprocessing your scans: separate misaligned areas (if any) into separate scans and cut out unwanted objects from the scene.
You may encounter the following problems:
- Misaligned frames (see Figure 67, left)—may occur because of small size, an insufficient number of geometrical features on the object or an insufficient number of polygons in a frame.
- Misaligned parts (see Figure 67, middle)—occurs when the real-time alignment algorithm incorrectly determines the position of the new frame relative to previous ones.
- Unwanted objects in the frame (see Figure 67, right).
A visual inspection of the frames can be very helpful in determining problematic areas. To perform a visual inspection, select the scan and view all the frames that it contains by holding ↑ or ↓ on the keyboard. This technique can easily detect misaligned frames.
When viewing scans, application generally shows only key frames and textured frames. To display all the frames, select the Show all frames option in the 3D toolbar.
See also
Separating Scans¶
During the fine-alignment process, frames in certain scans may be misaligned. Sometimes it’s possible to divide the problematic scan into several scans, where each part is registered fairly well. In this case, divide the scan. To move some of the frames into a new scan, use the following procedure:
- Select in the Surface List panel the frames you want to move (see Selecting Frames).
- Click RMB and select Move to new scan (Figure 52, right).
You can also fix alignment errors in another way: reset the current frame-transformation values and repeat the registration, making any appropriate changes to the settings. Select the desired scan in the Workspace panel, click on it using RMB and select Reset transformations from the dropdown menu. Doing so will reset the computed positions of individual frames in the scan. A dialog will then appear, prompting you to confirm the operation. To compute new positions, run the Rough serial registration and then Fine registration algorithms (see Fine Registration).
Alignment and Registration at a Glance¶
Registration and alignment tools perform similar tasks, however, they differ. Use the table below to get an insight into the details.
Type | Purpose | Details |
---|---|---|
Fine registration | Adjusting frames’ positions | Treat scans in batch separately. Starts once you leave Scan panel. |
Align | Assembling scans | See also Table 12 |
Global registration | Optimizing frames within scans | Launch it for a pre-aligned batch of scans or for a single scan |
Rough registration | Preliminary registration performed during scanning | No need to start it manually |
Editing Scans¶
To edit scans, open Editor from the side panel and select the Eraser tool. You can also use Positioning tool or Transformation tool to orient the scanned data.
Eliminating 3D-Noise (Outlier Removal)¶
During the scanning process, so-called outliers may appear in the scene. Outliers are small surfaces unconnected to the main surfaces. They require removal because they may spoil the model or produce unwanted fragments. Artec Studio provides two ways to remove outliers: erase them before fusion (preventive approach) or after fusion (“furthering” approach—see Small-Object Filter). We advise using the former approach because it decreases the possibility of improper fusion by preventing noisy features from attaching to the main surface.
This outlier-removal approach is based on a statistical algorithm that calculates for every surface point the mean distances between that point and a certain number of neighboring points, as well as the standard deviation of these distances. All points whose mean distances are greater than an interval defined by the global-distances mean and standard deviation are then classified as outliers and removed from the scene.
For better results, we recommend running global registration before starting the algorithm. If you begin Outlier removal before doing so, a dialog will appear prompting you to perform global registration.
In most cases, none of the parameters accessible through the button requires adjustment. But if necessary, you can change the values of these parameters:
- std_dev_mul_threshold
a standard-deviation multiplier. We recommend choosing the value for this parameter according to the following guidelines:
2: for noisier surfaces 3: for less noisy surfaces - resolution
- should be set equal to the resolution of the Fusion process that you expect to run later.
Click Apply to run Outlier removal.
Erasing Portions of Scans (Eraser)¶
Nearly always, the scanning process will capture unwanted elements, such as walls, the operator’s hands, surfaces on which the object is located and other extraneous objects. This unwanted data can hinder postprocessing. To avoid this problem, we recommend eliminating these objects before processing. Eraser offers several options to quickly and easily remove unwanted elements from the scene (see Selection Types).
- Open the Editor panel using the side toolbar.
- Open the Eraser tool by clicking or by hitting E.
- Select one or more scans in the Workspace panel.
- In the Editor panel, choose the required selection type.
- Consult the instructions for a specific mode and select regions on the scans that you want to erase. To clear all selections, click Deselect.
- Click Erase to eliminate the area highlighted in red or to apply cutting plane (Cutoff-plane or Base selections).
To undo changes, click in the Workspace panel or menu Edit, or hit Ctrl + Z. Each click of the Erase button generates a command history entry. To undo several operations, use the dropdown menu of button and select the lowest entry.
Selection Types¶
2D | Hold down Ctrl and use Scroll wheel to adjust the tool size. Paint with Ctrl+LMB to create a selection. | |
3D | See above. | |
Rectangular | Use Ctrl+LMB to select a rectangular region. | |
Lasso | Use Ctrl+LMB to freely outline an irregular region. | |
Cutoff-plane | Create selection as in 2D mode. Once you have released the mouse button, a plane will appear. If necessary, adjust the plane level by using Scroll wheel while holding down Ctrl+Shift or orient the plane freely in 3D space. To this end, hit Alt to display the designated control. Then still holding the key, drag the required control ring. | |
Base | Select a flat area as in 2D mode. The tool will automatically fit the base plane and select everything below it. |
If the Select through checkbox is selected, all surfaces throughout the scan are affected. If not, the brush only works on the visible surface.
Use the following general procedure to erase unwanted elements:
See also
More Actions With Selections¶
Apart from erasure, you can perform the following action with the selected regions:
- Clear selection to create a new one. Click Deselect or reselect the region manually while holding down Ctrl+Alt.
- Invert selection (clear the highlighted region and select the rest). It might be useful when working with large scans. Click Inverse or hit I.
- Temporarily hide selection if it obstructs the region you want to erase. Click Hide to this end. To display hidden polygons, click Show. Then select the region you want to erase.
Erasing Supporting Surface¶
Artec Studio offers two selection modes that differ from conventional brushes in the way how you select the area for erasure. First, you indicate the flat surface (table, floor or base) on which the object is resting. Then, application either determines the base plane and select the area underneath it (Base selection), or creates a cutting plane (Cutoff-plane selection) that divides the scan into two parts: the first will remain and the second will be erased (see Figure 73). You can orient this plane in any way you need.
Tip
Consider using the Enable automatic base removal option when scanning since it deletes the flat surface automatically after you close the Scan panel.
Fine Registration¶
Fine registration is an algorithm designed to automatically and precisely align captured frames. It starts once you complete scanning and close the Scan panel [1].
Note
Since the Fine registration algorithm runs automatically and uses the settings in the Tools panel, ensure that you have specified the proper (or, better, the default) values before you start scanning.
In a number of cases you can start the Fine registration algorithm manually using the Tools panel. To access a list of parameters, click the button in the Fine registration section. The algorithm affects all scans marked with the icon in the Workspace panel (see Selecting Scans and Models for more information on scan selection), but it processes them separately.
[1] | There is another post-scanning algorithm: automatic base removal (see Base Removal: Erasing a Supporting Surface.) |
From two to three parameters may be available. You can redefine either of them:
- registration_algorithm
is a type of registration algorithm
- Geometry_and_Texture
- takes both texture and geometry into account. If the scan lacks texture information, the algorithm will run on geometry only.
- Geometry
- uses geometry only. Unless your scan entirely lacks texture, we recommend avoiding this option.
- refine_serial
- is available as an option for Geometry_and_Texture mode. For this option to successfully register a scan, the same areas need to be captured in this scan using a “snake-walk” pattern. Wavy movements of the scanner will ensure the presence of the overlapping areas.
- loop_closure
- is an advanced algorithm that registers any frames not necessarily captured in series. Using any common regions in these frames, it compensates for cumulative error (see Figure 77) caused by the peculiarities of handheld-3D-scanner movements. We highly recommend enabling this algorithm when you’re scanning closed paths. It’s especially advantageous to use it in Geometry_and_Texture mode.
Figures below illustrate how each algorithm works if launched independently. The call-out boxes in each figure show two frames from the same corner of the door: one captured at the beginning and one at the end of the scanning session. The captured data (see Figure 75) has a cumulative error that is noticeable in the call-out box. The serial registration algorithm improves frames’ relative position (see Figure 76), but misalignments remain. The loop-closure algorithm eliminates these misalignment completely (see Figure 77).
Scan Alignment¶
Although Artec Studio features continuous scanning, there may be some cases where the application lack sufficient information about the relative positions of multiple scans. To assemble all scans into a single whole, you must convert the data to a single coordinate system—that is, you must perform alignment using the Align tool.
Hint
First refer to Auto-Alignment and take a glance at the Summary of Alignment Modes section as well.
Selecting Scans for Alignment¶
In the Workspace panel, use the flag to mark all scans that you intend to work with. Once you click Align in the side panel; the marked scans will appear in the left panel already selected in the same order as they appear in the Workspace panel. During the Align operation, Artec Studio divides the selected scans into two sets: aligned (registered) scans and unaligned scans. The first set initially contains only one scan (the first one in the list), which is highlighted in blue. Its name appears in bold and uses the same color icon (). Auto-Alignment, however, may produce several groups of aligned scans.
The user’s task is to align all scans to those that are already registered and to “assemble a model”. In general, the procedure includes the following steps:
Click the required tab in the Align panel.
Select one scan from the unregistered group in the Align panel. The name of unregistered scan appears in a regular typeface. When selected, the unregistered scan is marked by the green icon . You can select several scans using either of the following methods:
- Press and hold down the Ctrl key, and then click each scan that you want to select
- Click the first item, press and hold down the Shift key, and then click the last item.
If necessary, specify point pairs (for two scans) or sets of points (for more than two scans)
Click the desired alignment-command button (Auto-Alignment is the most recommended one). The command affects all scans selected in the Align panel plus the first one ().
Since each mode varies in its effects, see the details in the corresponding subsections for more information. Note that you can use either one mode or a series of modes (see comparison table in Summary of Alignment Modes): drag alignment, rigid alignment with and without point specification, automatic rigid alignment, and alignment with surface deformations.
Changing Scan Status¶
If you have already aligned several scans, you should move them to the registered group. Select them in the Align panel using LMB. Next, click RMB on the name of any scan and select the Mark as registered option from the dropdown menu, or just double-click its name in the list. At this point, Artec Studio will treat registered scans as one, so you cannot move them independently.
If you accidentally mark a scan as aligned, remove it from the registered group by selecting the Mark as unregistered item from the dropdown menu, or just double-click it.
Displaying Scans in 3D View¶
Scans selected in the Align panel appear in the 3D View window. Keys 1, 2 and 3 switch among scans in the 3D View window:
- 1
- shows aligned scans and groups
- 2
- shows scans that are currently under alignment
- 3
- shows all scans
Navigation in align mode is similar to navigation in the 3D View window:
- Rotate
- hold LMB and move mouse
- Zoom in/out
- Scroll the Mouse wheel, or hold RMB and move mouse
- Move freely
- hold LMB and RMB simultaneously, or hold the middle button, and move mouse
Summary of Alignment Modes¶
The table below provides basic information on the various alignment modes (see Scan Alignment).
- Scan type lists which scans you can use in a particular mode.
- Scans per operation is the number of scans required to use a particular mode.
- Markers in set prescribes how many markers (points) you can map in one point set. Some modes require point (marker) sets, but some don’t.
- “—” means that markers are unnecessary.
- “0 or 2” means point specification is optional and, if you do specify them, only marker pairs are allowed.
- “At least 1” means you can specify an unlimited number of markers in one set.
Mode | Scan Types | Scans per Operation | Markers in Set | Notes |
---|---|---|---|---|
Rigid (markers) | Any | 2 | 2 | Considers only coordinates, not geometry |
Rigid (meshes) | Any | 2 | 0 or 2 | Considers geometric features |
Rigid (texture) | Multiframe with poor geometry | 2 | 0 or 2 | High resource consumption |
Rigid (auto) | Any | Any number | — | Works if surface is well textured |
“Drag” | Any | 2 | — | Interactive |
Nonrigid | Models | Any number | 0 or 2 | Deforms surfaces and textures; pre-alignment required |
Complex | Any | 1 (at least 2 for models) | At least 1 | Precise and flexible |
Drag Alignment¶
Drag alignment is always available, regardless of which tab is active in the Align panel. This mode allows you to align scans by manually dragging them in the 3D View window.
Owing to the low accuracy of this approach, however, you can optionally use it for preliminary alignment before running more-accurate modes.
- Select the scan you want to align, keeping in mind the recommendation in Selecting Scans for Alignment. Artec Studio allows you to select multiple scans, but note that it will align them with the registered scans as a single unit.
- Holding down the Shift key and one mouse button, move and rotate the scan you’re aligning (a green one ) close to the registered scan (a blue one ). Here is a list of allowed movements and corresponding buttons:
- Shift+LMB to rotate
- Shift+LMB+RMB to move
- Shift+RMB or Shift+Scroll to move only unregistered scan along the view direction
- To confirm the alignment, release the mouse button(s) and the Shift key, then click Apply. Note carefully that any scans you are registering won’t automatically move to the registered set (see Figure 79). You can do so manually as the Changing Scan Status describes.
- If you have several scans to align, repeat these steps for each one individually.
Auto-Alignment¶
Rigid alignment is a universal mode suitable for aligning most scans. Auto-alignment is the easiest approach, however. The advantages of this latter mode include the ability to align several scans at once and avoid the need to specify points; the only disadvantage is minimum requirements for the size of the overlapping areas in the scans you’re aligning.
To perform auto-alignment, follow these steps:
- Make sure the Rigid tab is selected in the Align panel (see Figure 80). The tool will automatically select all scans. Clear unnecessary selections by using the Ctrl key (see Scan Alignment).
- Click Auto-alignment. Ideally, Artec Studio aligns all the scans and marks them using the icon. It may, however, mark scans as registered even though the 3D surfaces failed to join properly.
Important
Auto-alignment may be unsuccessful if the scans have small overlapping area.
Auto-alignment may produce the following results:
- Aligned scans, marked with the icon (basic group of registered scans)
- Unregistered scans, marked with the icon
- One group () or several groups (, ) of registered scans. Scans forming this group failed to align with the basic registered group (), although they succeeded in aligning with each other.
We recommend resolving issues with unregistered scans or registered groups by aligning them manually as Manual Rigid Alignment Using Point Specification describes. Other methods may also help.
Managing Groups and Scans¶
You can perform the following actions on the scans from the list in the Align panel (right-click on the item to open the context menu):
- Mark as registered
- Only available for single unregistered scans ( → )
- Mark as unregistered
- Use this command to discard the alignment state of a particular scan (unavailable for scans)
- Select group
- Highlights the respective group (, , and so on)
- Mark group as registered
- Converts all scans from the group into the basic registered group ( → )
Manual Rigid Alignment Without Specifying Points¶
You can perform rigid alignment either with or without specifying points. If the scans are close to each other in distance (e.g., after “drag” alignment), or if they have a large overlapping area or rich texture, you can skip the task of point specification when aligning them.
Perform the following steps:
- Make sure the Rigid tab is selected (see Figure 80).
- Select the scan you want to align, as the beginning of Scan Alignment describes.
- Click Align. The result should be as Figure 82 depicts. If you are dissatisfied with this result, click and follow the recommendations in Manual Rigid Alignment Using Point Specification.
- Select another scan from the list of unregistered scans and repeat the above procedure.
- Click Apply to confirm your alignment results or Cancel to reject them.
Texture Alignment¶
If the object was scanned with texture, the texture-alignment feature may ease the alignment process. It uses texture-image characteristics of scanned objects and greatly decreases the possibility of incorrect alignment. This feature also helps to align objects with few or no geometrical features, such as round or flat objects with no corners. If an object has rich, nonrepetitive geometry, however, we recommend disabling texture alignment to reduce the algorithm’s running time. Also keep in mind that texture alignment will be useless if the object texture is monochrome.
To enable texture alignment, select the Enable texture alignment checkbox at the bottom of the Align panel just before you perform Step 3 of the procedure above.
Note
Texture alignment is a resource-intensive algorithm that slows down the alignment process. We recommend using it only in cases where the object’s geometrical features are insufficient.
Specifying Points and Editing Their Positions¶
Before considering how to align scans using points, it is helpful to highlight point-pair specification. The alignment algorithm uses pairs of point, or point sets in “Complex alignment” mode (Complex Alignment), to detect scan areas that should be brought close together.
To do point alignment, create several point pairs. To create one pair, mark one point on the aligned scan and then mark another one on the unaligned scan. Ensure that in each case the points for a given pair match a corresponding point on the surface of a real object; note, however, that high matching accuracy is unnecessary, since Artec Studio only uses the pairs to gain a rough approximation before performing precise registration. In the Complex mode, you can create a set of points (instead of just a pair), i.e. you can simultaneously specify more than two points in one or several unregistered scans and only one in the registered scan. All these points are connected by polylines and form a set.
When specifying points in the Rigid and Nonrigid modes, the application automatically creates pairs. Having specified one pair, you can immediately create the next one. In Complex mode you must confirm set creation by hitting Space or by clicking New set from the left panel, because the set may comprise multiple points (see Figure 81 and Figure 87).
You can toggle between the point pairs (sets) by hitting Space and Backspace, or by clicking RMB in the 3D View window and selecting the relevant options from the menu. You can also relocate points in the pair (set). Hover the mouse cursor over the point until the pair (set) is highlighted in white, then drag the point to the proper position using LMB, or select the pair (set) and specify a new position using LMB. To confirm your actions and deselect the pair (set), hit Space. You can also remove either a pair (set) or one of its individual points: click on the point using RMB and choose the appropriate command from the menu. Alternatively, you can use Del to remove the selected pair (set).
Manual Rigid Alignment Using Point Specification¶
We advise using this mode when scans are located at a significant distance from each other.
To use this approach, follow these steps:
- Make sure the Rigid tab is selected (see Figure 80).
- Select the scan you want to align, as the beginning of Scan Alignment describes.
- Specify several point pairs (Figure 81), keeping in mind the recommendations from Specifying Points and Editing Their Positions.
- Click Align markers. This mode takes into account only the coordinates of specified points and tries to reduce the distance between the markers for each pair.
- Carry out Steps 3–5 of the procedure in Manual Rigid Alignment Without Specifying Points.
Nonrigid Alignment¶
Whereas rigid alignment can only perform such transformations as translation and rotation, the nonrigid algorithm can deform 3D data. This algorithm is intended to process so-called nonrigid objects: objects whose shapes have changed during the scan (e.g., models of animals or humans—see Figure 84, left). Keep in mind that the surface Artec Studio produces as a result of the deformation may differ from the surface of the actual object.
Note
Nonrigid alignment works on models only. Thus, before you run it, prepare models by fusing the source scans. It is also necessary to first align models in rigid mode (see Manual Rigid Alignment Without Specifying Points, Auto-Alignment or Manual Rigid Alignment Using Point Specification).
To run the nonrigid alignment, follow these steps:
Make sure the Nonrigid tab is selected (see Figure 83).
Select the models you want to align, as the beginning of Scan Alignment describes.
If the models differ significantly from each other, we suggest that you specify several point pairs, keeping in mind the recommendations in Specifying Points and Editing Their Positions.
Where necessary, adjust the deformation degree using the flexibility slider. The greater the flexibility value (i.e., the more “flexible” the deformation), the longer the computation will take.
Warning
Avoid extreme Flexibility values. Applying very large values may result in major surface distortions and may slow down the algorithm. Extremely low values, on the other hand, barely deform surface and often fail to produce the expected nonrigid-alignment results.
Click Align…. The algorithm will align models by deforming one of the model (see Figure 84, right). If you are dissatisfied with the alignment results, click and specify additional point pairs, or reposition the current pairs.
Select another model from the unregistered set and repeat the steps above.
Click Apply to confirm your alignment results or Cancel to reject them.
Note
This version of Artec Studio does not support texture mapping on nonrigidly aligned models.
Complex Alignment¶
Complex alignment allows you to align not only scan to scan, but surface to surface within a given scan (see the mode comparison in Summary of Alignment Modes). Relative to other modes, this one supports multipoint-set definition—that is, you can link more than two points. It’s useful for aligning scans obtained during circular movements of the 3D scanner in cases where fine registration with the loop_closure option enabled fails to align them. To run the Complex alignment, perform the following steps:
- Make sure the Complex tab is selected (see Figure 86).
- Select the scans you want to align, as the beginning of Scan Alignment describes. This mode allows you to work even with just one registered () scan.
- Specify one or more point sets on the scan surface (see Figure 87), keeping in mind the recommendations in Specifying Points and Editing Their Positions.
- Click Align… to run the alignment with your specified constraints (Figure 88 shows example results). If you are dissatisfied with the alignment results, click and specify additional point sets, or reposition the current sets. To redo an operation that you have undone, click .
- Click Apply to confirm your alignment results or Cancel to reject them.
Global Registration¶
Once you have aligned all your scans, proceed to the next stage: global registration. The global-registration algorithm converts all one-frame surfaces to a single coordinate system using information on the mutual position of each surface pair. To do so, it selects a set of special geometry points on each frame, followed by a search for pair matches between points on different frames. To perform correctly, the algorithm requires an initial approximation, which a user ensures in the course of the Align operation.
Note
Global registration is a resource-intensive operation. Processing of large data sets may take a long time and require a large amount of RAM.
To launch the algorithm, select all aligned scans in the Workspace panel. Next, open the Tools panel and locate the Global registration section. Click Apply.
Important
To successfully run on point cloud scans, global registration requires these surfaces to contain information on targets (spherical or checkerboard). Also ensure that the appropriate scanner type is selected.
Global-Registration Parameters¶
registration_algorithm | Geometry_and_Texture or Geometry | The type of algorithm that will perform scan registration. If an object has rich texture and poor geometry, consider using the Geometry_and_Texture option. For objects with rich geometry, you can choose Geometry mode to increase the registration speed. |
key_frame_ratio | 0–0.6 | Determines how many surfaces are treated as key frames. Decreasing this parameter when processing a feature-rich object may speed up registration. Increase it if only the previous attempts to register scans failed. Technically, values higher than 0.7 , including 1 , are possible, but they may significantly slow down the algorithm. |
feature_search_radius | 3–5 mm (Spider); 5 mm (Eva/Leo) and 50 mm in Geometry_and_Texture mode | Controls how sparse the features are located. Objects with many repetitive features may require decreasing this setting, whereas large values will ensure algorithm robustness on the big objects. Increase this parameter sparingly since large values may cause erroneous registration and hinder calculation. Adjust it if Fine Registration completes with inappropriate values of maximum errors. |
Possible Global-Registration Errors¶
- After the global-registration algorithm finishes, the frames are in disarray (see Figure 89, left) or the frame positions are unchanged. This error occurs because the application is configured for a different scanner type than the one that captured the data. Change the device type in the application settings (see Algorithm Settings).
- The algorithm has completed successfully, but a gap exists between two or more scans (see Figure 89, right). Select just these scans in the Workspace panel and run the global-registration algorithm. If the scans have drawn closer to each other but have failed to align after the algorithm finishes, increase the number of iterations and rerun the algorithm. Repeat this process until you achieve full alignment, then run global registration once again for all data. If you are unable to align several problematic scans, try aligning just two of them, then gradually increase the number of scans until all of them are aligned.
Ray Scan Triangulation¶
Application offers two ways to convert point-cloud surfaces to the commonly used models:
- Fusion operation
- Special triangulation algorithm
The latter approach is preferable to fusion in terms of speed. It generates a polygonal mesh from the original point cloud by simplifying its structure.
To launch this algorithm, follow the steps:
- Mark a scan from Artec Ray using flag in the Workspace panel.
- Access Tools from the left toolbar.
- If necessary, specify the decimationStep and set either of the threshold filters.
- Click Apply.
decimationStep | 1–10 | The larger the value, the more the points will be culled. 1 leaves the point cloud unchanged. 2 culls half of the points, 4 keeps some 25% of the total amount of points, 10 about 10%. |
minimumAngle | 1–60 | Triangles with angles smaller than specified limit (in degrees) won’t be created in the resulting mesh. Extremely large values that are out of the recommended range may yield no mesh. |
maxIncidenceAngle | 0.1–90 [2] | If the angle between the normal to triangle and the scanner view direction is larger than the specified one, this triangle is subject to removal. |
maxEdgeLength | Above 0.1 mm [2] | Algorithm will remove triangles whose edge lengths are greater than the specified value. |
[2] | (1, 2) Use 0 value to disable a particular filter. |
Creating Models (Fusion)¶
Fusion is a process that creates a polygonal 3D model. It effectively melts and solidifies the captured and processed frames. Fusion is the most interesting part of the processing task because a polygonal 3D model is what most people expect to see when performing a 3D scan. To this end, you can use one of the following algorithms, each of which has a self-explanatory name (see also the summary in Table 13):
- Fast fusion produces quick results.
- Smooth fusion is good for scanning the human body because of its ability to compensate for slight movements by the person you’re scanning.
- Sharp fusion perfectly reconstructs fine features and is suited to both industrial objects and human bodies. It is the only mode that allows you to use all the capabilities of a Artec Spider scanner.
Fast Fusion | Smooth Fusion | Sharp Fusion | |
---|---|---|---|
Usage | Fast results for large data sets; also for measurements | Large, noisy data sets with patchy missing regions; scans of moving objects | Scans from Artec Spider; scans having regions with fine details and sharp edges |
EVA | resolution no less than 0.5 | ||
Spider | resolution no less than 0.15 | ||
L | resolution no less than 1.5 | ||
Fill_holes | Not applicable | Available | |
Features | Resulting surfaces are relatively noisy. | Smoother results. Can compensate for slight movements, but not recommended for accurate measurements. Relatively slow. | Higher level of detail. Faster than Smooth fusion, but may intensify existing noise. |
To obtain a model:
- Make sure the scans you intend to fuse have passed Global registration.
- Select the scans in the Workspace panel using .
- Enter the Tools panel.
- Select the necessary mode; optionally, specify parameter values.
- Click Apply.
- View the model in the 3D View window and in the Workspace panel once the algorithm finishes. The model name will match the algorithm name.
The fusion algorithms use the following parameters:
- resolution
- —the step of the grid (in millimeters) that the algorithm uses to reconstruct a polygonal model. In other words, this parameter defines the mean distance between two points in a model. The lower the resolution value, the sharper the shape. When specifying values, keep in mind the default values, lower limits in Table 13 and Max error.
- Fill_holes
—instructs the algorithm to fill holes in the mesh being reconstructed; option unavailable for Fast fusion. The methods for filling the holes are as follows:
- By_radius
- —fills all holes with radius less than or equal to the specified value in the max_hole_radius text box (in millimeters)
- Watertight
- —automatically fills all holes in the mesh
- Manually
- —prompts you to fill holes manually in the Fix holes panel, which opens automatically
- remove_targets
- —allows you to erase small embossments from surfaces on which targets are placed (see Target-Assisted Scanning). Parameter can assume either the On or Off value; unavailable for Fast fusion.
Fusion-Algorithm Errors¶
Occasionally, defects appear in the 3D model after fusion; some are correctable by creating additional scans, whereas others are correctable by using the model-processing tools described in the next section.
Errors that can be corrected by capturing additional scans include low-amplitude noise on the surface (see Figure 92, left). Normally, this error indicates that the affected area has a small number of frames. The number of frames needed to eliminate the noise depends on the reflective properties of the object’s surface. To correct the error, you need one more scan to cover the noisy area (see Figure 92, right).
Sometimes the cause of noise is an insufficient number of scanning angles. Areas captured at a larger angle have more noise than areas captured at a direct angle (i.e., 90 degrees). You can correct this error by scanning the area again using a better angle.
When the scanning conditions or the object features are such that you are unable to capture additional data, you can correct errors using the Fix holes (see Filling Holes and Smoothing Edges) or Smoothing (Smoothing (Tools)) tools. If such errors are frequent, reduce the speed at which you move the scanner around the object, or increase the capture rate (see Decreasing Scanning Speed).
Editing Models¶
The resulting fusion model may contain surface defects due to scanning or registration errors. Artec Studio provides a number of tools to correct such errors:
- Repair
- —corrects the model’s triangulation errors
- Small-object filter
- —removes small objects located near the model surface
- Fix holes
- —semiautomatically fills holes and smooths the model edges
- Hole filling
- —fills holes in the model automatically
- Smoothing
- —filters low-amplitude noise over the whole model
- Smoothing brush
- —enables manual smoothing of the surface areas with the most noise
- Mesh simplification
- —reduces the number of polygons in a model while minimizing lost accuracy
- Isotropic remesh
- —creates isotropic mesh while keeping the processed mesh as close to the original as possible
Each algorithm processes all scans selected in the Workspace panel and replaces the original data with the results. If the algorithm is unsuccessful, you can restore the original data by clicking (Undo) in the Workspace panel.
Small-Object Filter¶
If you forgot to erase outliers before fusion (see Eliminating 3D-Noise (Outlier Removal)), Artec Studio may solidify and preserve them in the scene as small, distant fragments.
You can effectively remove these remaining outliers by using a filtering algorithm.
To remove these artifacts, select in the Workspace panel only the model you are currently editing, then open the Tools panel. Click Apply next to Small-object filter to run the algorithm (see Figure 93). A window containing algorithm settings will appear when you click . You can adjust the following parameters:
- mode
- —the Leave_biggest_objects option from the dropdown menu instructs the algorithm to erase all objects except the one with the most polygons; Filter_by_threshold erases from the scene all objects whose number of polygons is less than the amount specified in the threshold parameter.
- threshold
- —the maximum number of polygons for Filter_by_threshold.
Defeature Brush (Editor)¶
Erasing certain geometrical imperfections often demands further processing of the resulting holes in the model. The Defeature brush combines functions of the Eraser and Hole filling tools and may boost your productivity. To use it, follow these steps:
Warning
If you edit a textured model, note the following. Since the texture will incorrectly fit the altered surface, the Defeature brush will remove it from the model. So you will need to repeat texturing after you finish editing.
- Select one model in the Workspace panel.
- Open the Editor panel using the side toolbar and click either Defeature brush or hit D.
- In the Editor panel, choose the required selection type.
- Consult the instructions for each mode and select regions on the model that you want to modify. To clear all selections, click Deselect.
- Click Apply. The software will delete the feature, close up the hole and smooth the surface.
To undo changes, click in the Workspace panel or menu Edit, or hit Ctrl + Z. Each click of the Apply button generates a command history entry. To undo several operations, use the dropdown menu of button and select the lowest entry.
Selection Types¶
2D | Hold down Ctrl and use Scroll wheel to adjust the tool size. Paint with Ctrl+LMB to create a selection. | |
3D | See above. | |
Rectangular | Use Ctrl+LMB to select a rectangular region. | |
Lasso | Use Ctrl+LMB to freely outline an irregular region. | |
Cutoff-plane | Create selection as in 2D mode. Once you have released the mouse button, a plane will appear. If necessary, adjust the plane level by using Scroll wheel while holding down Ctrl+Shift or orient the plane freely in 3D space. To this end, hit Alt to display the designated control. Then still holding the key, drag the required control ring. |
If you need to deselect any region, hold Ctrl + Alt and reselect this region. To clear all selections, click Deselect.
If the Select through checkbox is selected, all surfaces throughout the model are affected. If not, the brush only works on the visible surface.
See also
Smoothing¶
Smoothing (Tools)¶
The smoothing algorithm evens out noisy areas in the 3D model. Artec Studio provides two such tools: automatic smoothing of the entire model and manual smoothing of specific areas identified using a brush (see Smoothing Brush (Editor)).
To run the automatic smoothing algorithm, open the Tools panel and select Smoothing. You need only set one parameter:
- steps
- —the number of algorithm iterations to be performed
Smoothing Brush (Editor)¶
The Smoothing brush is a tool that you can employ selectively in specific areas without touching areas that require no alteration (for more information about automatic smoothing, consult Smoothing (Tools)).
To use the Smoothing brush,
Select just one model.
Hit Ctrl, an orange region will appear around the cursor in the 3D View window.
Change brush size if necessary:
- Use either the Ctrl + [ and Ctrl + ] shortcuts or
- Use Scroll wheel.
- Enter a size (in millimeters) in the Brush size field.
- Alternatively, you can adjust the slider bar in the Smoothing brush panel.
Set the smoothing strength if necessary:
- Enter the desired value in the Smoothing strength field or
- Adjust the slider bar.
Hold LMB and paint the surface region in order to smooth it. The tool will smooth the affected areas (see Figure 96, right).
To undo changes, click in the Workspace panel or hit Ctrl + Z as many times as needed to return to the original state of the model since each brush stroke generates a command history entry.
Hole Filling¶
Automatic Hole Filling¶
To quickly and automatically fill holes, use the Hole filling algorithm in the Tools panel. It employs the same edges as the Fix holes tool, processing only those holes with parameters that correspond to the one user-adjustable setting, which you can access through the button:
- max_hole_len
- maximum length of the hole perimeter in millimeters. The algorithm only processes holes with perimeters below this threshold.
Filling Holes and Smoothing Edges¶
Sometimes the shape of an object or the scanning conditions prevent you from properly capturing of all parts of the scene. As a result, the fused 3D model will have holes. In such instances, you can use the hole-filling tool to interpolate the surface.
To start analyzing and correcting the model,
Select the model and click Fix holes from the side panel. The new panel has two tabs: Edges and Holes, each of which contains a list of holes detected on the surface. These defects are sorted by their perimeter length.
Select a hole, Artec Studio will highlight the corresponding edge in the 3D View window.
Note
If the Move camera to selection option is checked, the model will automatically rotate to display the selected edge. By default, the camera moves smoothly from one edge to another when switching between edges. If the model is large, however, this movement may take too long. To expedite the switch, clear the Animate camera checkbox.
To select edges for correction,
- Mark the checkbox next to each one you wish to correct. These edges will be highlighted in red in the 3D View window (see Figure 98).
- Use the Select all and Deselect all buttons in the panel to select or clear all selections, respectively.
- You can also select edges right on the model. To do so, rotate the model to make the edge visible in the 3D View window. Then click LMB to select it.
Under the Holes tab, you can enable an option that automatically smooths the holes after filling them by checking the Smooth holes after filling box (see also Smoothing (Tools)). Under the Edges tab, use the Strength slider to control the edge-smoothing intensity. Also, you can use this tab to smooth part of the edge instead of the whole one. To do so, rotate the model to make the edge visible and mark it in the list as “processing required.” Next, hold down LMB and move the mouse over the edge to drag apart the ends of the profile to the desired position (see Figure 100).
After you have selected all the edges or the holes you want to fix, click Fill holes or Smooth edges. Artec Studio will repair the model. If the results are satisfactory, click Apply to confirm them; otherwise, you can always use the button to cancel any changes. If you try to exit the Fix holes mode without accepting changes, the software will ask you for confirmation.
Mesh Simplification¶
The mesh produced after fusion may be less than optimal for some applications because it will contain a large number of polygons. This complexity will increase the amount of memory the model occupies, hindering further processing. To optimize the model size while retaining accuracy, use the Mesh simplification algorithm.
Select the model and open the Tools panel. You can choose from two algorithms.
Conventional Algorithm¶
Open the dropdown algorithm settings by clicking the button next to Mesh simplification. Select the appropriate processing method (determined by the stop_condition):
- Accuracy
- —optimize model to a predetermined accuracy: the error parameter defines the optimized model’s maximum allowable deviation (in millimeters) from the original model. When the algorithm reaches this value, the optimization stops.
- Remesh
- —perform simple mesh optimization, removing triangles whose edge lengths are less than the remesh_edge_thr value (in millimeters).
- Triangle_quantity
—simplify the model by targeting the number of triangles specified in the tri_num parameter. The algorithm minimizes the resulting model’s deviation from the original model, but the final deviation value will remain unknown until processing concludes. Use this method when you know how many triangles the resulting model should have.
Tip
To determine the number of triangles, double-click the appropriate model from the list in the Workspace panel (see Figure 53).
- UV_Triangle_quantity
- —similar to the Triangle_quantity algorithm, but intended for meshes with textures mapped by the Atlas method (see Applying Texture (Procedure)). This approach not only simplifies the polygon grid, reducing the number of triangles, but it preserves texture.
- UV_Vertex_quantity
- —simplify a textured model by targeting the number of vertices specified in the vrt_num parameter.
Tip
Since the UV methods tend to slightly reduce texture resolution, we recommend using either of them only when no raw scans are available. It is generally better to simplify models using one of the regular method and then reapply texture.
The three first algorithms in the list above have additional parameters:
- keep_boundary
- —maintain the model boundary. Mesh simplification on the scan edges may affect their geometry. Thus, if the shape of the boundaries is more important than the optimized mesh, select the On value. Otherwise, select Off, and the algorithm will simplify the boundary mesh.
- max_neighb_normals_angle
- —the angle between the normals of two neighboring faces. You can specify an angle (default value is 120°) to prevent Artec Studio from creating degenerate triangles. If the angle measure in some region exceeds the specified value, the algorithm will leave the mesh unchanged in that region. Note that the default value is appropriate in most circumstances.
After adjusting the algorithm settings, click Apply to start processing.
Note
Mesh simplification may take a long time when the parameters of the original and optimized models are significantly different (for example, if the deviation value is high in Accuracy mode or if the required number of polygons in Triangle_quantity mode is much smaller than the number in the original model). For very large 3D models the operation requires extensive memory resources and may fail owing to insufficient RAM. Free the memory by closing unused applications and by optimizing memory usage in Artec Studio, keeping in mind the recommendations in Memory, Command History and Selectively Loading Project Data.
Fast Mesh Simplification¶
The Fast mesh simplification algorithm works faster than the conventional one. To run it, perform these steps:
Open the dropdown algorithm settings by clicking the button next to Fast mesh simplification.
Specify in the tri_num text box the desired number of triangles for the resulting model. You can determine how many are in the actual model by double-clicking it in the Workspace window.
Set the force_constraints option:
- If this option is set to Off, the value specified in the tri_num text box remains constant.
- If this option is set to On and the algorithm is unable to produce a surface with the specified number of triangles (tri_num), Artec Studio will automatically update this value. In other words, improving the quality of the resulting surface is the primary objective.
Click Apply to run the algorithm.
Texturing¶
Artec scanners are equipped with a color camera, allowing you to capture 3D surfaces with texture and expanding the range of objects available for scanning. Texturing is a process that projects textures from the individual frames onto the fused mesh.
Preparing Model¶
To take advantage of texture, do the following:
- Make sure the Don’t record texture checkbox is cleared.
- Adjust the capture frequency for texture frames (see Texture-Recording Mode) if necessary.
- Avoid turning off the flash bulb.
- Adjust the texture brightness in Preview mode by using the eponymous slider in the Scan panel.
- Scan the object using a tracking algorithm of your choice. Captured frames are marked with the letter “T” in the Workspace panel (surface-view mode) (see Figure 52, right).
- Process the data and create a model, consulting the list in the beginning of Data Processing or Autopilot.
- Run a mesh-simplification algorithm for the resulting model (see Mesh Simplification) to accelerate the texturing process.
- Use the Texture panel to apply the texture to the model.
Applying Texture (Procedure)¶
The 3D model obtained after fusion contains no texture information. To apply textures onto a model, do the following:
Open the Texture panel
Choose a model from the first list (see Figure 104); Artec Studio will apply the textures to this model
Select from the second list the scans from which you created the model (these scans have the required textures)
Next, choose a method for applying textures to the model. Artec Studio offers two methods:
- Preview (triangle map)
- Export (texture atlas)
Select the required Output texture size [3] and other options as necessary (Supplementary Settings)
Click Apply to start the texturing process [4]
Finally, when the texture is ready, adjust it as necessary.
[3] | Texturing with the 16K resolution (16384x16384) is only available if your graphics card features at least 3 GB of GPU memory. |
[4] | To optimize resource utilization, Artec Studio unloads all surfaces from memory, except those needed for texturing, before running the applying procedure. For a more detailed description of selective project-data loading, see Selectively Loading Project Data. |
To reduce or increase the resolution (Output texture size) of the already applied texture, you can re-apply it several times faster by enabling the Export (reuse UV map) option.
Warning
We recommend that you avoid applying texture to models that have undergone major changes in geometry or orientation. The algorithm will apply the texture incorrectly if you have done any of the following:
- Position or transform the model relative to its source scans
- Nonrigid Alignment
- Erase major parts of the model
Perform these operations only after texturing.
Modes¶
Mode | Texture Distortion | Speed | Number of Textures | Texture-Resolution Management |
---|---|---|---|---|
For preview | Does not preserve aspect ratio of triangles | Fast | One or more | Adjust triangle size and texture-image resolution |
For export | Preserves aspect ratio of triangles | Slow | Only one | Adjust texture-image resolution |
Texturing for Preview (Triangle Map)¶
The Preview method transfers all textured triangles to a square texture image (or a series of images). You can adjust the Triangle size (in pixels) [5] using the eponymous slider (see Figure 105, right). To select the resulting texture size, use the dropdown list (maximum texture size depends on the capabilities of your graphics card). After changing the triangle/texture size, the estimated number of textures will appear in the Estimated area at the bottom of the panel; the actual number may differ slightly, however.
[5] | Triangle size is determined by the number of pixels per side. |
Texturing for Export (Texture Atlas)¶
The Export method cuts the surface into pieces, then unfolds and nests these pieces flat and fits them into the specified image size (see Figure 105 (middle) and Figure 61 in Displaying Boundaries of Texture Atlas). This method takes longer to run than Preview, but the resulting texture is much more convenient for manual editing.
Supplementary Settings¶
To modify a texture using an inpainting technique, use one of these two options:
- Inpaint missing texture
- allows you to apply a texture to regions with no texture information by spreading it from the neighboring regions.
- Remove targets
- does the same thing, painting out targets by applying surrounding texture information (targets are used to facilitate scanning—see Target-Assisted Scanning). This option makes sense if you enabled remove_targets before producing this fusion model (see Creating Models (Fusion)).
- Enable texture normalization
- this option is selected by default. It aims to compensate for uneven lighting caused by movement of a scanner’s flash unit during capture. We recommend leaving this option enabled.
Texture Adjustment¶
After the texturing is complete, you can adjust the texture on the model (see Figure 107).
You can adjust the following texture parameters by way of the corresponding sliders (see Figure 106 for details):
- Brightness
- Saturation
- Hue
- Contrast
- Gamma correction
The initial position of the Hue slider corresponds to the current texture color. Dragging it left or right corresponds to rotation counterclockwise or clockwise, respectively, on the color wheel.
After making the necessary changes, click Apply to transfer the resulting textured model to the Workspace panel.
To reopen the texture-adjustment dialog, follow the steps:
- Select a textured model in Workspace.
- Use RMB to call the context menu.
- Select the Adjust texture command from the list.
Texture-Healing Brush: Manual Inpainting¶
You can manually inpaint missing textures by using the Texture-healing brush. This tool is based on the same algorithm as the Inpaint missing texture option covered in Applying Texture (Procedure). The inpainting algorithm uses texture information from neighboring regions to fill in areas with missing or incorrect texture. Left image in Figure 108 shows a small texture imperfection: a felt-tip pen mark on the figurine. Results of inpainting this region appear in Figure 108 (right).
To launch the tool and inpaint a texture, do the following:
Hint
We advise you to first back up your model by selecting the Duplicate scans command from its context menu since the undo function is unavailable in this tool.
Mark the model textured for Export with the flag.
Important
This version of Artec Studio does not support texture restoration on the models ‘textured for Preview’ (triangle map) and in regions of any models that have been corrected using the Defeature brush.
Open the Editor panel by clicking its icon in the side toolbar.
Select the Texture-healing brush.
Hold down Ctrl while using Scroll wheel or [ and ] keys to adjust the tool size. It should not exceed the size of the region that needs texture correction.
Paint over the region of interest using LMB while holding down Ctrl so that the tool (a circle or a spot) only rolls over the problem area. Try to avoid touching neighboring areas. Use the Deselect button to clear all the selections.
Repeat the previous step as necessary.
Click Apply to accept the changes or close the panel to reject them.
Note
If you paint an area in which the number of polygons exceeds the value specified in the settings dialog (see Warnings), a message will appear prompting you to either ignore the value, which means that processing may take longer, or cancel the operation.
Preparing Models To Export¶
Moving, Rotating and Scaling (Transformation Tool)¶
The Transformation tool allows you to move, rotate or scale objects in the 3D View window.
To access this tool, open the Editor panel and select Transformation tool or hit T. The panel will open, displaying four tabs that correspond to different modes for altering the object position in the global coordinate system. The name of the active mode appears at the bottom of the 3D View window.
- To enter translation mode,
click the Translate tab or hit T. Three input fields will appear in the Editor panel showing the current origin coordinates (in millimeters) of the local coordinate system. The initial position of the local coordinate system will be in the center of the global one. To translate an object, do either of the following:
- Enter the new coordinate values for the local system using the input fields in the Editor panel. To adjust the position only along a specific axis, first hit the corresponding X, Y or Z key.
- Translate the object in the 3D View window by dragging the corresponding control (see Figure 109):
- Square in the center to move it freely
- Arrow to move it along a specific axis
- Lines between arrows to move it along the two axes simultaneously
Note
Orienting the object may be easier if you first specify a new position for the origin of the local coordinate system: double-click on the desired surface point in the 3D View window.
- To enter rotation mode,
click the Rotate tab or hit R. Three input fields containing the Euler-angle values will appear in the Editor panel. Initially, all values are set to zero. To rotate the object, do either of the following:
- Enter the new angle values (in degrees) using the input fields in the Editor panel.
- Drag one of the three circles (see Figure 110) to rotate the object. Hitting the key that corresponds the required axis (X, Y or Z) will hide the controls for the other axes.
Note
Orienting the object may be easier if you first specify a new position for the center of the local coordinate system: double-click on the desired surface point in the 3D View window.
- To enter scaling mode,
click the Scale tab or hit S. A single input field with the current scale value (1.000) will appear in the Editor panel. You have two options for scaling the object:
- Enter the new scale value in the field.
- Drag the origin of the control (Figure 111) or either of its round ends in the 3D View window.
After altering the object using any of the methods described above, confirm or cancel your changes by clicking Apply or Reset, respectively.
Each time you click Apply, Artec Studio will save the object position in the project history. Therefore, you can revert to the initial object position using the (Undo) button in the Workspace panel.
Placing Objects on Coordinate Plane (Positioning Tool)¶
You may need to place the model on one of the coordinate planes (e.g., for aesthetic reasons or when preparing the model for measurements, for capturing a screenshot, for exporting and so on). Instead of adjusting the model position using the Rotate and Translate modes of the Transformation tool, you can use the special Positioning tool. To do so, follow these steps below.
Tip
The Enable automatic base removal option may come in useful to position scans automatically after the scanning completes (see Base Removal: Erasing a Supporting Surface.)
Open the Editor panel from the side toolbar and click either Positioning tool button or hit P.
Ensure that the coordinate axis grid is shown. Otherwise hit G or select the Grid command from 3D toolbar.
Choose the coordinate plane in which you want to place the model by activating one of the following options: XOY, YOZ or ZOX. Note that you may skip this step and return to it after Step 3.
Use LMB to specify at least three points on the surface; the plane will automatically pass through their center of mass (see Figure 112). The following conditions will then apply:
For each additional point you specify, Artec Studio rebuilds the plane. Click Clear points at any time to redefine the points.
Note
Three points determine a plane. When you’re dealing with nonplanar surfaces, however, three points may be insufficient. In that case, the more points you specify, the more precisely a plane will fit the surface.
In addition to the plane passing through the center of mass of the points you select, the coordinate origin will shift to that location as well.
The position of the coordinate origin is adjustable, as described below.
Invert the direction of the coordinate axis, if desired, by clicking the Invert Z button for the XOY plane, Invert X for YOZ, or Invert Y for ZOX.
If appropriate, adjust the model’s position relative to the coordinate origin:
- Shift + LMB—rotate the model around the axis that is currently normal to the plane
- Shift + RMB—move the model along the plane in a fixed direction
- Shift + LMB + RMB—move freely along the plane
Hit Apply to fix the model on a specified plane or close the panel to cancel positioning.
To discard changes of object position, click in the Workspace panel or hit Ctrl+Z.
Advanced Techniques¶
Automatic Processing¶
See also
Automatic processing is a special mode for the Tools panel that saves time and simplifies postprocessing. It allows you to run all postprocessing algorithms from the Tools panel (Rough, Fine and Global registration; Fast, Smooth and Sharp fusion; Small-object filter or Outlier removal; Hole filling; Mesh simplification; Remesh; and Smoothing) with a click of just one button.
To switch from manual to automatic mode, open the Tools panel and choose the Auto option from the dropdown list in the left corner. Click the button near Go! to view all options available in automatic mode. Note that only Global registration, Fast fusion and Small-object filter are enabled by default. To perform other actions automatically, choose the On option in the dropdown list next to the required function, or choose Off to exclude a function from automatic processing. Click Go! or hit Ctrl + G to begin automatic processing.
Each algorithm setting and parameter is based on the values for manual mode. To change these values, switch to Manual mode, make the necessary alterations and then run automatic processing—Artec Studio will apply all changes.
Keep in mind that the algorithms run in the order in which they are listed, starting with Rough serial registration and ending with Remesh. Thus, if you want to run the Small-object filter before Fast fusion or Global registration, for instance, you must do so manually.
Unlike manual processing, automatic processing runs without the need for constant user attention, so it is more convenient when processing large objects: you can configure the settings, start the process and leave it unattended. It can also process objects of any size, reducing the number of mouse clicks to get the result.
Isotropic Remesh¶
Note
Don’t confuse it with the remesh parameter in Mesh simplification.
Isotropic remesh is an operation that modifies 3D model in the way that new mesh triangles have uniform size. Software packages where the models from Artec Studio are intended to be used may impose these requirements.
The algorithm produces an isotropic mesh, but doesn’t necessarily decrease the polygon count. However, the output file is often smaller than the original one through the uniform triangles.
To produce a uniform mesh,
Normal Inversion¶
Normal direction determines the visibility of a surface in 3D graphics. Learn how to show normals of the objects in Artec Studio 3D View, see Representation of Normals and Boundaries.
Normal inversion allows one to turn the model inside out. This operation may be useful when you need to manufacture some mating parts, like molds; or obtain a model based on its cast (e.g., turn the footprint cast into a shoe last, see Figure 115).
To invert normals on a particular model,
Correcting Triangulation Errors¶
Some algorithms may introduce triangulation errors into the resulting model. These errors include the following:
- Unattached vertices
- —points that are not vertices of any of the triangles
- Vertices with identical coordinates
- —vertices that have the same coordinates
- Faces containing invalid vertices
- —triangles that point to nonexistent vertices
- Singular faces
- —triangles for which at least two of the three vertices coincide.
- Faces with equal signature
- —faces with fully coinciding sets of vertices
- Edges incident to three or more faces
- —edges that are adjacent to three or more faces
- Faces with wrong orientation
- —faces whose normals point in a direction opposite to those of the adjoining faces
To correct these errors, mark a model in the Workspace panel by using the flag and hit Ctrl + R or select the menu command. If the algorithm detects no triangulation errors, Artec Studio will notify you that it has found no defects. Otherwise, the Repair panel will open, displaying the above-mentioned list of defects to be corrected. Next to the names of the defects, a column will appear stating the number of defects of a certain type found in the model. You can select all defects by pressing View all. Doing so will display in the model all the defective vertices and triangles using colored points. You can disable display of any particular defect type by removing the icon next to the corresponding name, or disable them all by clicking View none. To correct the defects, click Repair all. Clicking the Apply button accepts the changes.